intelligentterew.blogg.se

Q-Lab Master Slave Control
q-lab master slave control






















The industry standard.outside world, and the data from the master is transferred to the slave. Upon reception, the steps are reversed.KAS (PDMM) as a Profinet Slave - Setup for Siemens S7-1200 PLCOnce you master the basics, become a power user with advanced features like scripting, video corner pinning, multi-projector edge blending, audio localization, or even building multi-computer designs by sending commands to other QLab machines on your local network. The MSDU is then COBS encoded by MS/TP. Maximum Transmission Unit (MTU) Upon transmission, the network-layer MTU is formatted according to Section 5 and becomes the MAC service data unit (MSDU). Standards Track Page 7 RFC 8163 IPv6 over MS/TP (6LoBAC) May 2017 4.

The Studio Force V range also features stand-alone Master and Slave modes for.the investigation on masterslave chaotic CS of Lur’e system based on a new LyapunovKrasovskii functional. 12 Build 2, 12, 0, 72029 and Siemens TIA Portal V15.Details Downloads Technical Specifications Control & Photometric Data. Wire up a single section of this chip, andUsing KAS IDE Version: 2. The 7476 is a dual master-slave JK FF. Observe the sequence of data flow from the master to the slave.

(digital performer/Qlab/reaper etc) so a master and a slave I am already using the.Starting with new projects in TIA Portal and the KAS IDE, follow these steps to create the necessary parts of the projects to support the communication.1. Basically, the PLC will only be setting values for some variables in the KAS program.In my band a mac plays the backing tracks and controls video. The KAS program controls the servo axes. The Profinet communication is intended to support the transfer of data between PLC variables and KAS variables. In this case, the PLC is the master and the PDMM is the slave device. Since the threshold worked out the-oretically is much small, Liao and Chen 8 used an assistantThis is a step by step procedure for setting up a Siemens S7-1200 PLC and a PDMM (KAS) for Profinet communication.

Open the Device View and select the PDMM device. This will create the Profinet network link between the PLC and the slave device.3. In the Network View, click on the hyperlink “Not assigned” and select the PLC device (“PLC_PROFINET interface_1”). Drag and Drop “KAS PN-IO device” into the Network View.2.

Q-Lab Master Slave Control Download The Project

The KAS device under Distributed I/O should indicate a “Not reachable” error. You will see red icons indicating an error. Click on PLC_1 in the project tree and compile and download the project. (Uncheck the box for “Generate PROFINET device name automatically”.) This name is the Profinet name that the PLC will use to identify the PDMM.If you choose to check the box for “Generate PROFINET device name automatically”, TIA will use the device module name for the Profinet device name and the Converted name.4. Also enter the Profinet device name. In the Ethernet addresses section, enter the IP address of the PDMM.

You can also use an existing project.2. For this example, I selected PLCopen and 2 Axes FFLD, but you can choose any type of project you want. Once everything is set up properly and the KAS program is running, you will see these icons turn green.1.

Select PROFINET IO device, since the PDMM will be the Profinet slave device.4. Use the toolbar in the Fieldbus Editor to create a fieldbus configuration.3. Click on Fieldbus to open the Fieldbus Editor.

A slot is used as a reference number for the data that will be transferred over Profinet.6. Click the “Configure slots” button and configure at least one slot. The Default station name is the Profinet name defined in the PDMM.5. Enter “tsec0” for the Adapter Identification.Remember the Profinet Device Name that you entered in TIA Portal? Enter that same name for the Default Station name.

q-lab master slave control

Outputs are data that are output from the PLC.9. Inputs are data that are input to the PLC. Set the Subslot to Do this for the inputs and outputs. Select or create a variable and enter the slot number to want to map to that variable. Give it a name and select the Type (input or output).8.

In TIA Portal, open the Device View, and select the PDMM (KAS) device.3. Instead of entering the Profinet device name in the KAS fieldbus settings for Default station name, leave the Default station name blank.2. If you stop the KAS program, then the Profinet communication will be stopped.Alternative Method for Defining the KAS Profinet Device Name Through TIA Portal:1. When the KAS program is running, it will support Profinet communication.

Drag and drop the input and output modules that you need into the PDMM (KAS) device module list in the corresponding slots. Open the Device View and select the PDMM (KAS) device.4. Click the “Assign name” button to send the name specified in TIA Portal to the Default station name in KAS.Assigning Module Addresses in TIA Portal:2. Click the “Update list” button to search of devices on the network.If a Default station name was previously defined in KAS, then TIA will find that name and indicate that it is different from the name specified in TIA Portal.If the PDMM was never configured with a Default Station Name, then that will be indicated in the status.5.

q-lab master slave control

You can now force values of the outputs from TIA and force values of the inputs from KAS. Each address number is one byte.8. A 32bit module will use two Words, the first at address 256-257 and the second at address 258-259.

I suspect that KAS is also using some sort of converted name that is all lower case letters.Methods for setting the PxMM’s Profinet name:1. It will use whatever was last set in the "Default station name".Upper case letters do not seem to matter. You must specify this name in KAS or assign it through TIA.Deleting the "Default station name" will not clear the Profinet Device Name from KAS. The name in the master must be identical to the name in the slave.The name of the slave device module in TIA is irrelevant, unless you check the box for "Generate Profinet device name automatically".The "Configuration name" in KAS is irrelevant.The "Default station name" in KAS is used for the Profinet Device Name.Set this to the same as in TIA and it will work.By default, there is no name. This name is used to automatically configure the "Converted name".The "Converted name" in TIA is used for referencing the Profinet device name of the slave device.

Set the "PROFINET device name" (and "Converted name") in TIA, and ignore the "Default station name" in KAS. Profinet communication will be established.2. Compile and download both projects.

But you will not see any change of the value/text of the "Default station name" in KAS IDE. The same methods apply for making sure the name in the PLC matches the name in KAS.The "Default station name" in KAS is the name used for Profinet communications.When doing an "Assign Profinet device name" via TIA to change the PxMM's Profinet name, the name will change. But it will establish communication.Checkbox for "Generate Profinet device name automatically":If you check the box for "Generate Profinet device name automatically", TIA will copy the "Module name" into the "PROFINET device name" and "Converted name". The PxMM device will accept the new name and use it for communication, but the KAS IDE will not indicate a change in the value of "Default station name".

q-lab master slave control